Real Time ARINC-429
Analyzer Software
WINDOWS
ARINC-429 Data Analyzer software is supplied with any of the ARINC429 PC cards, thus
providing a complete turn-key solution.
The PC software has been designed to run on a PC running Microsoft Windows™ 98/NT4/2000 (later operating systems,
including XP, will also be supported – check with YED for further information).
However, YED can't guarantee functionality if the software is loaded on a
non-English language PC.
The package comprises Real Time
Simulation, Data Monitor, Data Recorder and Data Analyzer functions and has the
following features:
-
DEDICATED SHORTCUT BUTTONS:
navigation buttons
are available from the main screen. Green open buttons indicate that a set-up
file has been assigned to the channel and has a corresponding save icon.
Yellow open buttons indicate that no set-up file has been assigned. Assignment
is by clicking on the button and selecting the set-up database to be assigned.
Other buttons available are for short-cuts to the transmission screen, the bus
search screen, the bus monitor screen, the data acquisition screen and to the
help index respectively.

- USER DEFINABLE ENGINEERING UNITS:
Allows definition
of custom Engineering
Unit display formats so that data can be viewed and entered in engineering units
formats. Supported Data conversion formats include: Unsigned Binary, Signed
Binary, Two's Compliment Binary, Binary Coded Decimal (BCD) and Discrete data
(Flags). Multiple fields within a data word are possible. i.e. Discrete/Flags
mixed with a Binary field within a single word.
- REAL TIME BUS ACTIVITY:
Performs Bus Activity
operations. Displays any data present on any of the receive channels in Binary
and Hexadecimal formats. Receive Speed is automatically detected and displayed.
- REAL TIME MONITOR WITH ENGINEERING UNITS DISPLAY:
Displays selected ARINC Labels and their
associated data words. The display formats available in this mode are Binary,
Hexadecimal and Engineering Units. ARINC Labels (TAGS) can be selected for
display by Channel, Label, SDI and SSM.
- REAL TIME SIMULATION:
Entered data can be in
Engineering units or Hexadecimal formats as previously described above. Data can
be entered in Real Time. Other programmable features include variable
Inter-Word-gaps (IWG - usually set to 4 bit periods), programmable intervals
including different embedded rates within a major frame for all labels,
programmable Parity, SSM and Data rates. Single Shot mode is also supported.
- RAMPING:
Allows transmitted label data to be
configured so that data values are automatically ramped up and down during
transmission. This feature is ideal for running tests where ARINC429
parameters need to be varied between defined limits in order to simulate "live
data".
- DATA ACQUISITION TO HARD DISK AND REVIEW OF RECORDED
DATA:
Data for capture to disk can be selected by Label and SDI prior to
initiating the capture so that the size of the resultant data file size is kept
to a minimum. Data record time is only limited by the available capacity of the
resident hard drive.
- POST PROCESSING:
As well as presetting parameters for
recording data to disk, the embedded Post Processing functions of the package
allows additional selection criteria to be applied to the captured data file.
Data can be selected again by Label and SDI and additionally, only 'Changing
Data' can be specified so that only data that has changed in value since
the last occurrence is displayed.
- POWERFUL SEARCH TOOLS:
enables quick location
of specific labels.
Search is by Label, SDI and SSM. Searches can also be performed where the point
of interest can be specified by the occurrence of a data value. The conditions
are 'Less than', 'Greater than or Equal to' a given value.
- GOTO:
Clicking on the 'Go To' button displays a dialog box from which a time
within the data capture period can be selected. The time of the last captured
label (in seconds) is also displayed. The display will refresh displaying data starting at the
time requested for that channel.
- SAVE FILE TO DISK:
enables the captured data
to be saved to disk. This data
can be recalled at any time and re-displayed.
- EXPORT TO SPREADSHEET:
enables export of the captured data in a
file format compatible with ExcelTM.
- LABEL DEFINITION SEARCH & COPY:
allows a search
for a particular label number (in octal) within a specified labels database
file and then to copy the label definition to an existing or to a new labels
set-up database file.
- ON LINE CONTEXT SENSITIVE HELP:
makes this package so easy and
intuitive to use, a separate User Manual isn't really necessary, but is however
supplied.
Click
here to Download the brochure in Acrobat PDF format (259kB).
Click
here to download the User Manual
for ARINC429 software in Acrobat (PDF) Format [Size: 532kB - Date: 18 Feb 2005]
[PASSWORD PROTECTED - To request password click here.]